Certificates :
Application
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles,
in most areas & on open deck in ships.
* Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see technical information section
CONDUCTOR : Electrolytic, stranded, annealed sector shaped copper wire to IEC 60228 Class 5 SM (Tinned on request)
INSULATION : Cross linked polyethylene compound (XLPE).
INNER COVERING : Separating foil.
OUTER SHEATH : Halogen-free, flame retardant, polyolefin based compound (SHF 1).
COLOR : Black or Grey.
CONSTRUCTION : EC 60092 / 353
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT : IEC 60332 / 1, IEC 60332 / 3-22 Cat A
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESISTANCE : IEC 60811 / 403
WORKING TEMPERATURE : -40°C / + 90°C
MIN. BENDING RADIUS (FIXED) : For cables D ≤ 25 mm 4xD
For cables D > 25 mm 6xD
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
Cross Section (mm2) | Overall Diameter (mm) (*) | Approximate Weight (kg / km) | Min. Bending Radius Fixed Installed (mm) | Max Resistance of Conductors at 20°C (ohm / km) | Current Carrying Capacity at 45°C (A) |
---|---|---|---|---|---|
3×35 | 21.2 | 1125 | 128 | 0.554 | 107 |
3×50 | 25.6 | 1575 | 154 | 0.386 | 137 |
3×70 | 29.1 | 2240 | 175 | 0.272 | 168 |
3×95 | 31.8 | 2845 | 191 | 0.206 | 201 |
3×120 | 37.4 | 3640 | 225 | 0.161 | 233 |
3×150 | 41.3 | 4415 | 248 | 0.129 | 268 |
3×185 | 46 | 5350 | 276 | 0.106 | 303 |
3×240 | 51.5 | 7150 | 309 | 0.0801 | 356 |
4×35 | 25.1 | 1495 | 151 | 0.554 | 107 |
4×50 | 28.8 | 2045 | 173 | 0.386 | 137 |
4×70 | 33.7 | 2960 | 203 | 0.272 | 168 |
4×95 | 37 | 3760 | 222 | 0.206 | 201 |
4×120 | 41.3 | 4795 | 248 | 0.161 | 233 |
4×150 | 45.5 | 5795 | 273 | 0.129 | 268 |
4×185 | 51 | 7050 | 306 | 0.106 | 303 |
4×240 | 56.3 | 9420 | 338 | 0.0801 | 356 |